Skip to content
NormenNS-1Vorgeschlagen
NS-1

NS-1: Die UNI und der Artefaktkatalog (Grammatik v0.2

NS-1 is a proposed Nexus Standard; the artefacts it governs are identified by UNIs (Unique Nexus Identifier). NS-1 gives every artefact the ecosystem produces one stable, machine-readable identifier, the UNI (Unique Nexus Identifier), and one catalogue record that says what the artefact is, who made it, who publishes it, what rights apply and where it lives. Code, services, schemas, datasets, models, reports, articles, figures, maps, lessons, policies and standards all follow the same scheme, so any agent, developer, researcher, machine or expert reader can find and cite an artefact the same way across all systems, rooms, runtimes, organisations and sites.

NS-1 im Katalog
The standards NS-1 depends on and those that cite it, then its sections with one mark for each numbered requirement.Source: NS-1-identifier-and-artifact-catalog.md; the Nexus Standards registry.
  • NS-1 hängt ab von: NS-2, NS-3, NS-3b, NS-4, NS-5, NS-6, NS-7, NS-8, NS-9, NS-13, NS-16.
  • NS-1 wird zitiert von: NS-0, NS-2, NS-3, NS-3b, NS-4, NS-6, NS-7, NS-9, NS-10, NS-13, NS-15, NS-16.
  • Abschnitt 1, Wo der Standard verortet ist: keine nummerierte Anforderung.
  • Abschnitt 2, Die UNI: keine nummerierte Anforderung.
  • Abschnitt 3, Scope codes: keine nummerierte Anforderung.
  • Abschnitt 4, Kategoriecodes: keine nummerierte Anforderung.
  • Abschnitt 5, Die Aufzeichnung: keine nummerierte Anforderung.
  • Abschnitt 6, Regeln: R1, R2, R3, R4, R5, R6, R7, R8, R9, R10.
  • Abschnitt 7, Einbettung: wie jede Oberfläche die UNI trägt: keine nummerierte Anforderung.
  • Section 8, Commands: no numbered requirement.
  • Abschnitt 9, Der Stack offener Standards: keine nummerierte Anforderung.
  • Abschnitt 10, Verhältnis zu den anderen Standards: keine nummerierte Anforderung.
  • Section 11, Follow-on packages: no numbered requirement.
01Überblick

Zusammenfassung

NS-1Datensatz
  1. Statusproposed
  2. VerantwortungsbereichVertrauen
  3. Festgelegte Regeln10
  4. Programmbereiche10
  5. QuelldateienRepository

Nexus Standards · proposed

Anforderungen
10
nummerierte Regeln
Abschnitte
11
im Text
Hängt ab von
11
NS-2, NS-3, NS-3b
Zitiert von
12
Nexus Standards
02Der Standard

NS-1: der Standard

Der Text von NS-1 in der Fassung des kanonischen Repositorys (Commit 2cbe0d41b5f8): 11 Klauseln, 2 Unterklauseln und 10 identifizierte Anforderungen, jeweils mit Anker und Zitierangabe.

Code
NS-1
Titel
Die UNI und der Artefaktkatalog (Grammatik v0.2: Segmente für Domäne, Sektor, Region und Umwelt)
Version
0.1.0
Status
VORGESCHLAGEN
Datum
catalogue 2026-10-15 · circulated 17 October 2026
Unique Nexus Identifier
NXS-STD-ST-000001
Verantwortungsbereich
Vertrauen
Quelle
standards/NS-1-identifier-and-artifact-catalog.md at 2cbe0d41b5f8

Preparatory working draft, circulated for review and comment. Not for implementation. Prepared and circulated by Saeed Valadbaygi, Chief Steward, Nexus Standards (saeed@therisk.global), 17 October 2026. Technical review area: TR-02. This document is not a Nexus Standard; it may change without notice and is not to be implemented, relied upon or cited as a Nexus Standard. Its stage is designated only by the Global Standards Council and its technical committees under NS-13. Recipients are invited to submit comments with supporting reasons, and to notify any patent rights of which they are aware. See the notice of circulation.

Status
VORGESCHLAGEN
Inhaber
the trust and assurance system (trust, authorisation, policy and assurance; NXS-S13)
Ausstellungsstruktur
UNI-Kennungsgewebe
Kanonische Heimat
this repository
Machine registry
registry/nexus-standards.yaml
Datensatzschema
schemas/nexus-artifact-record.v1.json
STD catalogue
catalog/artifact-catalog.yaml
Referenz-CLI
node tools/nexus-id.mjs
Umsetzungen durch Verbraucher
registry/consumers.yaml

NS-1 gives every artefact the ecosystem produces one stable, machine-readable identifier, the UNI (Unique Nexus Identifier), and one catalogue record that says what the artefact is, who made it, who publishes it, what rights apply and where it lives. Code, services, schemas, datasets, models, reports, articles, figures, maps, lessons, policies and standards all follow the same scheme, so any agent, developer, researcher, machine or expert reader can find and cite an artefact the same way across all systems, rooms, runtimes, organisations and sites.

das Vertrauens- und Sicherungssystem besitzt die Nexus Standards und führt ihre Versionen. Jedes andere System, jede Site-Engine, jede redaktionelle Oberfläche und jeder Agent wendet sie an und spaltet sie nie ab. Ein UNI identifiziert und löst auf; er bescheinigt nie Wahrheit, Bereitschaft oder Autorität (V3-Richtlinie, Abschnitt 12).

ZitierenNS-1, clause 0. NXS-STD-ST-000001@0.1.0. https://nexustandards.com/standards/ns-1/#nx-c-0

0. Wo der Standard liegt

This repository is the canonical home of the Nexus Standards: the documents under standards/, the machine registry under registry/, das Datensatzschema unter schemas/, the STD-scope catalogue under catalog/ und die Referenz-CLI unter tools/. Consuming repositories (nexus-foundry, the WordPress plugin, institutional sites) implement the standard, keep their own catalogues for their own scopes, and never fork the registry; registry/consumers.yaml lists them with their status. Paths written as server/..., src/... or scripts/... in diesem Dokument sind Pfade innerhalb des Konsumenten nexus-foundry.

ZitierenNS-1, clause 1. NXS-STD-ST-000001@0.1.0. https://nexustandards.com/standards/ns-1/#nx-c-1

1. Die UNI

Grammatikversion 0.2 (Kontextsegmente am 2026-10-16 hinzugefügt; jede Kennung der Version 0.1 ist unverändert und weiterhin gültig).

NXS-<SCOPE>-<CAT>[-<DOMAIN>][-<SECTOR>][-<REGION>][-<ENV>]-<SERIAL>[@<VERSION>] NXS-EWS-DS-000042                    dataset 42 of the early-warning system NXS-EWS-DS-KEN-000003                a Kenyan early-warning dataset NXS-GRX-RP-M002-000007@1.2.0         report 7 of the data system for Africa, version 1.2.0 NXS-GRX-AR-WAT-CAN-000012            article 12 of the data system on water in Canada NXS-GRX-DP-WAT-WUT-CAN-PRD-000001    production deployment 1 of the data system for Canadian water utilities (NS-9) NXS-GCR-AR-000015                    an article published by GCRI Canada NXS-STD-ST-000001                    this standard
SegmentFormularBedeutung
NXSfestPräfix. Gewählt gegenüber NEX weil er wie ein Code und nicht wie ein Wort gelesen wird; NEX- ist von Marken überlaufen (Nexo, Nexi, Nexor) und NXS ist bereits das neutrale Systempräfix in public-identity.json
SCOPEdrei BuchstabenEin kanonisches System (EWS, EOP, SIG, GRX, OPS...), eine Organisation (GCR, GRF, GRA, NXO) oder einen übergreifenden Geltungsbereich (STD, LEG, GOV, PRG)
CATzwei BuchstabenArtefact category, mapped to Zenodo upload and publication types and to DataCite resource types; or an NXS-GRX (canonical data, provenance and risk) record kind (OB, SR, IN, ME, BD, CT, CR, AP, SU, NS-3). Die beiden Listen teilen nie einen Code
DOMAINoptional, drei BuchstabenNexus-Domänencode aus registry/domains.yaml (WAT Wasser, ENE Energie, FOO Ernährung, HLT Gesundheit, BIO Biodiversität, CLI Klima, DRR, EWN, HUM, INF, SCH, SEC, ZTA, FNC, DSC, ERM, DRG, AIS, DAT, GSP, PRV, IDF, SFW, NAT, SDP, LIC; vorgeschlagen: CMP, DTW, SNS, PNT)
SECTORoptional, drei BuchstabenSektorcode aus registry/sectors.yaml (AGR, WUT, EUT, HSY, FNI, TRL, CIT, INM, DTC, PUB, RED, HUO, IGO)
REGIONoptionalISO 3166-1 alpha-3 (KEN, CAN) oder UN-M49-Region als M + drei Ziffern (M002 Afrika, M142 Asien); Register registry/regions.yaml
ENVoptional, drei BuchstabenPRD Produktion, STG Staging, LBX Labor, FIX Testdatensatz (Fixture); von kontextuellen Datensätzen verwendet (NS-9)
SERIALsechs ZiffernAllocated by the catalogue or the UNI fabric per full prefix (SCOPE + CAT + context segments), never reused
VERSIONoptionalSemantic version of an artefact (1.2.0) oder die ganze Zahl recordVersion eines NXS-GRX-Datensatzes (3, NS-3). Die UNI ohne Version benennt das Konzept

Kontextsegmente. Die vier optionalen Segmente erscheinen stets in der Reihenfolge DOMAIN, SECTOR, REGION, ENV; jedes ist ein dreibuchstabiger Code aus seinem Register, und die Register sind paarweise disjunkt sowie disjunkt zu den Geltungsbereichscodes und zur M49-Form (geprüft durch tools/nexus-id.mjs catalog validate), sodass eine Kennung ohne Trennzeichen deterministisch geparst wird. Die Kennung ohne CAT und SERIAL ist der Kontextname, NXS-GRX-WAT-CAN: das Datensystem, Domäne Wasser, Kanada. Der Kontextname ist das, was Artikel, Seiten, Datensätze, Bereitstellungen, Dashboards und Code zu diesem Kontext als ihren Namen tragen (NS-16); ihre UNIs unterscheiden sich nur in CAT und SERIAL. Ein Kontextname wird nie vergeben und trägt nie eine laufende Nummer; der kontextuelle Datensatz nach NS-9 (DP or PR) ist der maßgebliche Datensatz für einen Kontext.

Maschinenlesbare Formen: URN urn:nexus:uni:NXS-EWS-DS-000042; Auflösungspfad /uni/NXS-EWS-DS-000042 (HTML-Zielseite für Browser, JSON für Maschinen, /uni/<uni>.json immer JSON; /uni listet veröffentlichte Datensätze auf); Kontextpfad /ctx/NXS-GRX-WAT-CAN (jeder veröffentlichte Datensatz dieses Kontexts); Feldname uni in jedem Datensatz, jeder API, jedem Schema und jeder Tabelle.

Bestehende Kennungen mit Punkten (grix.eo.stac.catalogue) sind UNI v0. Sie werden erfasst als legacyUni auf dem neuen Datensatz zur Zuordnung und werden nie wieder vergeben.

ZitierenNS-1, clause 1.1. NXS-STD-ST-000001@0.1.0. https://nexustandards.com/standards/ns-1/#nx-c-1-1

1.1 Vergabe von Kontextcodes

Vorschlag NXS-STD-PC-000004 führt diesen Abschnitt ein und ist OFFEN; die Regeln gelten für jeden ab jetzt vergebenen Code. Maschinenlesbare Form: registry/nexus-standards.yaml identifier.codeAllocation. Prüfen: node tools/nexus-id.mjs catalog validate.

Ein Geltungsbereichs-, Domänen-, Sektor- oder Umgebungscode ist eine dreibuchstabige Klassifikation, die Maschinen auswerten und die Menschen nie lesen müssen. Die Vergaberegeln stellen sicher, dass kein Code je mehrdeutig wird, auch nicht nach künftigen Änderungen anderer Codelisten.

RegelText
CA-1Drei Großbuchstaben A–Z. Keine Ziffern, und niemals das M + dreistellige Form von UN M49.
CA-2Eindeutig über alle Register hinweg: Geltungsbereiche, Domänen, Sektoren, Umgebungen und ISO 3166-1 alpha-3.
CA-3Niemals eines der folgenden, alle aufgeführt in registry/regions.yaml, so a future country assignment cannot collide:
• an ISO 3166-1 exceptionally, transitionally or formerly reserved code element;
• a code in the user-assigned ranges (AAA–AAZ, QMA–QZZ, XAA–XZZ, ZZA–ZZZ);
• an ICAO Doc 9303 nationality code.
CA-4Mnemonik der englischen Bezeichnung: der erste Buchstabe des Kernbegriffs der Bezeichnung, gefolgt von Konsonanten, die den Code erkennbar halten.
CA-5Niemals ein Produktname, eine Marke, ein Firmenname oder ein Börsenkürzel und niemals ein Wort, das wie eine Marke wirkt.
CA-6Ein Konzept je Code. Jeder Code hat eine Definition, was er einschließt und ausschließt, und die externen Standards, auf die er abgebildet wird.
CA-7Kennungen sind stabil, englisch in Kleinbuchstaben im Kebab-Case. Bezeichnungen stehen in Satzschreibung. Keines von beiden kodiert einen Status.
CA-8Nur anhängen. Ein Code wird nie neu vergeben oder gelöscht. Ein ausgemusterter Code behält seinen Eintrag mit deprecated: true und supersededBy.
CA-9Ein neuer Code bleibt PROPOSED, with its proposal UNI, until the Global Standards Council adopts the registry change. Consumers may use a PROPOSED identifier but must show its status.
CA-10Das Hinzufügen eines Codes ist eine Nebenversion des Registers (additiv). Die Änderung der Bedeutung eines Codes ist eine Hauptänderung und erfordert eine Zuordnungstabelle.

Bestandsgeschützt: AAP, der Systemgeltungsbereich des Systems für vorausschauendes Handeln. Er wurde vor CA-3 vergeben und liegt im vom Nutzer vergebenen Bereich AAA–AAZ. Er bleibt bestehen, gemäß CA-8.

Unter diesen Regeln vorgeschlagene Technologiedomänen:

CodeIdKennzeichnungZuordnungen zu
CMPcomputeRechen- und beschleunigte InfrastrukturISO/IEC JTC 1/SC 38 and SC 39; ISO/IEC 22123
DTWdigital-twinsDigitale Zwillinge und SimulationISO/IEC 30173:2023; ISO/IEC JTC 1/SC 41; ISO 23247
SNSsensingSensorik- und MessnetzeOGC SensorThings API und SensorML; W3C/OGC SOSA/SSN; IEEE 1451
PNTpntPositionierung, Navigation und ZeitgebungIEEE 1588; ITU-T G.8271 and G.8272; ITU-R TF series; UN ICG

Sensorik und Positionierung-Navigation-Zeitgebung sind getrennte Codes, weil verschiedene Communitys sie standardisieren: Sensor- und Beobachtungskodierungen auf der einen Seite, Zeitgebungs- und GNSS-Profile auf der anderen. Ein Technologiestrang, der beides abdeckt, trägt SNS und Listen PNT als verwandt.

Ein künftiger Quantentechnologie-Code kann nicht QTM or QNT, weil beide in den vom Nutzer vergebenen Bereich fallen QMA–QZZ. CA-3 erkennt diese Art von Kollision vor der Vergabe.

ZitierenNS-1, clause 2. NXS-STD-ST-000001@0.1.0. https://nexustandards.com/standards/ns-1/#nx-c-2

2. Geltungsbereichscodes

SystemCodeSystemCode
Nexus (Haltung, Management-Synthese)CMDsig (Signal, Zeitgebung, PNT)SIG
northstar (gemeinsames Lagebild)NSTnsf (trust, authorisation)das Vertrauens- und Sicherungssystem
dss (decisions)DSSHub (Wissen, Datensätze)HUB
nexcore (Berechnung, Laufzeitumgebungen)CORstudio (composition, workflows)STU
nexq (packages, models, capabilities)NXQFactory (Builds, Signierung)FAC
grix (Daten, Herkunft, Risiko)GRXapps (Anwendungslebenszyklus)APP
eop (earth observation)EOPSchienen (Vereinbarungen, Protokolle)RLS
ews (early warning)EWSPortale (öffentlich, für Kunden, für die Bereitstellung durch Partner)POR
aap (anticipatory action)AAPLabs (Forschung, Simulationen)LAB
net (network continuity)NET
op (Instrumente, Kalibrierung)OPS

Organisationen: GCR The Global Centre for Risk and Innovation (GCRI Canada) · GRF Das Global Risks Forum · GRA Die Global Risks Alliance · NXO das Konsortium · ELP und OBS reservierte Organisationsbereiche (vor der Verwendung zurückgezogen; parsbar, nie vergeben). Bereichsübergreifend: STD Standards · LEG Recht und geistiges Eigentum · GOV Governance · PRG Programm · UXK UI/UX-Kit · ALL ecosystem-wide.

Bereichscodes sind Klassifikation, keine Namen. Öffentliche Bezeichnungen folgen dem Standard zur Namensarchitektur (nexus-foundry the network's own records); the trust and assurance system als Code ist in Ordnung, „das Vertrauens- und Absicherungssystem“ als öffentlicher Produktname dagegen nicht. Die kanonische systemId und neutralId bleiben unverändert.

ZitierenNS-1, clause 3. NXS-STD-ST-000001@0.1.0. https://nexustandards.com/standards/ns-1/#nx-c-3

3. Kategoriecodes

CodeArtefactZenodoDataCite
SWSoftwareSoftwareSoftware
SVDienst oder APISoftwareDienst
SCSchema oder VertragsonstigeSonstiges
MGDatenbankmigrationSoftwareSoftware
WFArbeitsablaufworkflowArbeitsablauf
MDModellModellModell
DSDatensatzDatensatzDatensatz
EVEvidenzakteDatensatzDatensatz
ARArtikelpublication / articleJournalArticle
PPPreprintpublication / preprintPreprint
RPBerichtpublication / reportBericht
TNTechnische Notizpublication / technicalnoteText
DCDokumentationpublication / softwaredocumentationText
DLArbeitsergebnispublication / deliverableBericht
WPArbeitspapierpublication / workingpaperText
BKBuch oder Kapitelpublication / bookBuch
CPKonferenzbeitragpublication / conferencepaperConferencePaper
THAbschlussarbeitpublication / thesisDissertation
PTPatentpublication / patentSonstiges
STNormpublication / otherNorm
PCRichtlinie oder Weisungpublication / otherText
PSPräsentationPräsentationText
POPosterPosterText
FGAbbildungimage / figureBild
PLPlot or visualisationimage / plotBild
DGDiagrammimage / diagramBild
PHFotoimage / photoBild
MPKartenproduktimage / otherBild
VDVideoVideoAudiovisuell
LSLektion oder KursLektionInteractiveResource
PYPhysisches ObjektphysicalobjectPhysicalObject
PABeteiligungsdatensatzsonstigeSonstiges
RSStatusdatensatz des ProgrammssonstigeSonstiges
OTSonstigessonstigeSonstiges

node tools/nexus-id.mjs export <uni> --format zenodo produces Zenodo deposition metadata; --format datacite produces a DataCite-shaped record, so a catalogued artefact can be deposited or minted a DOI without re-describing it.

ZitierenNS-1, clause 3.1. NXS-STD-ST-000001@0.1.0. https://nexustandards.com/standards/ns-1/#nx-c-3-1

3.1 Der öffentliche Registry-Crosswalk

Das Registry unter therisk.global/nexus-registry/ (Herausgeber GCRI Canada) zeigt Datensatzkennungen NX-R-nnnnn (Programmstatus), NX-P-nnnnn (Veröffentlichung), NX-E-nnnnn (evidence) and NX-C-nnnnn (Teilnahme) mit Version, Hash und Status. Diese Formen werden zu Anzeigealiasen von UNIs: NX-R-47092 → NXS-GCR-RS-047092, NX-P → RP (oder AR, PP, WP, wenn der Datensatz dies angibt), NX-E → EV, NX-C → PA. Die Registry-Version wird zu currentVersion, der Hash versions[].digest, the state registryState (REGISTERED, CORRECTION_OPEN, RIGHTS_HOLD, WITHDRAWN). Die Seite weist darauf hin, dass noch kein öffentlicher Datensatz veröffentlicht wurde, sodass nichts Aktives bricht. Vollständige Regel: registry/nexus-standards.yaml#registryCrosswalk.

ZitierenNS-1, clause 4. NXS-STD-ST-000001@0.1.0. https://nexustandards.com/standards/ns-1/#nx-c-4

4. Der Eintrag

Each UNI has one record in the catalogue (schema: nexus-artifact-record.v1.json). Erforderlich: uni, title, scope, category, status, creators, publisherRef, publicationDate, rights, legalState, claimCeiling, locations. Optional: region, systemId, legacyUni, description, keywords, language, currentVersion, versions (mit Git-SHA und sha256-Digest), relatedIdentifiers (DataCite-Beziehungstypen, sodass Teile, Ableitungen, Ablösungen und Zitierungen einen Graphen bilden), supersededBy, workPackageId, directiveRefs.

Assurance fields: legalState ist standardmäßig LEGAL_REVIEW_REQUIRED; claimCeiling übersteigt nie das Schadenregister (FIXTURE_VERIFIED, IMPLEMENTATION_COMPLETE, INTEGRATED, LAB_OBSERVED); publisherRef is the institution for institutional artefacts (the institution stays publisher of record; ownership of the technology does not make its owner the publisher).

ZitierenNS-1, clause 5. NXS-STD-ST-000001@0.1.0. https://nexustandards.com/standards/ns-1/#nx-c-5

5. Regeln

RegelText
NS1-R1One UNI per artefact concept; versions share the UNI and differ in @VERSION
NS1-R2UNIs are allocated only through the catalogue (mint); nie von Hand eingegeben
NS1-R3UNIs are never deleted or reused. Withdrawn artefacts keep their record (WITHDRAWN); ersetzte halten fest supersededBy
NS1-R4Jede Aufzeichnung trägt die erforderlichen Metadaten; legalState Standardwert ist „Prüfung erforderlich“; claimCeiling bleibt innerhalb des Anspruchsregisters
NS1-R5The UNI is embedded in the artefact itself so machines and people can find the record (section 6)
NS1-R6Regional artefacts carry REGION; public regional or national use still follows the name architecture's geographic rules
NS1-R7Codes dienen der Klassifikation, nie als Produktnamen
NS1-R8Neue Codes für Geltungsbereich, Domäne, Sektor und Umgebung erfüllen die Vergaberegeln CA-1 bis CA-10 (Abschnitt 1.1) und werden über einen Vorschlag nach NS-13 eingebracht
NS1-R9Ein Code wird nie neu vergeben oder gelöscht; ein stillgelegter Code wird als veraltet gekennzeichnet mit supersededBy, und Kennungen, die ihn verwenden, bleiben gültig
NS1-R10A PROPOSED identifier may be used and is shown with its status until the registry change is adopted
ZitierenNS-1, clause 6. NXS-STD-ST-000001@0.1.0. https://nexustandards.com/standards/ns-1/#nx-c-6

6. Einbettung: wie jede Oberfläche die UNI trägt

OberflächeInhaberHow
Quelldateiendas Vertrauens- und SicherungssystemKopfkommentar Nexus-UNI: <uni>
Dokumente und BerichteHUBVorspann uni: oder erste Verteidigungslinie Nexus-UNI: <uni>
Datensätze und ProdukteGRXSidecar <file>.uni.json mit dem Datensatz, oder eine uni Schlüssel in STAC- und DataCite-Metadaten
Abbildungen und KartenEOPBildunterschrift-Suffix [<uni>] und Bildmetadaten
Foundry HTTP APIsdas Vertrauens- und SicherungssystemResponse header X-Nexus-UNI: <uni> bei jeder JSON-Antwort, deren Inhalt ein uni (server/middleware/uniHeader.ts); GET /api/uni/catalog, GET /api/uni/:uni, GET /api/uni/:uni/export?format=zenodo|datacite|schema-org|codemeta|citation-cff|stac|dcat|prov im Rahmen des Geltungsbereichs des Vertrauens- und Sicherungssystems; öffentlich GET /uni/:uni for PUBLISHED, non-restricted records with Schema.org JSON-LD
Räume und PanelsSTURoom-binding projects the payload uni (oder uniKey) je Quelle und zeigt sie als Link an; jede Zelle, die eine UNI ist, verweist auf /uni/<uni>; the trust and assurance system room's Standards surface reads the catalogue (ns6StandardsRoomDefinitions.ts)
PassportsGRXPASSPORT_UNI_FIELD (nexus:uni) ist das erste Feld des gemeinsamen Abschnitts Identity; Format uni verknüpft gültige UNIs mit /uni/<uni> and shows legacy dotted ids unlinked; the account passport links its registered UNI
Landing- und Trust-SeitenPOR<meta name="nexus-uni" content="<uni>"> und data-nexus-uni auf der Stammebene der Komponente
WordPress-Plugin und institutionelle WebsitesPORBeitragsmetadaten _nexus_uni (validated; uni im REST-Body zur Herkunft), <meta name="nexus-uni"> und X-Nexus-UNI sind im Plugin eingebunden (the network's own records); Blockattribut nexusUni follows in NS-6. See nexus-foundry the network's own records
Agentendas Vertrauens- und SicherungssystemMint through the CLI and embed the UNI in every artefact produced

Jede Oberfläche in registry/nexus-standards.yaml#surfaces hat einen Status. Eine Oberfläche ohne erklärte Einbettung ist nicht konform; PLANNED bedeutet, dass der Hook spezifiziert, aber noch nicht angebunden ist. NS-6 hat den API-Header und die Routen, Räume und Pässe angebunden; Meta-Tags der Landingpages und JSON-LD folgen mit den Resolver-Seiten (NS-7).

ZitierenNS-1, clause 7. NXS-STD-ST-000001@0.1.0. https://nexustandards.com/standards/ns-1/#nx-c-7

7. Befehle

node tools/nexus-id.mjs validate NXS-EWS-DS-000042 node tools/nexus-id.mjs parse NXS-GRX-RP-M002-000007@1.2.0 node tools/nexus-id.mjs next --scope EWS --category DS --region KEN node tools/nexus-id.mjs mint --scope EWS --category DS --title "Kenya flood observations 2026" \ --path the approved sources of the network --region KEN --publisher GCRI_CANADA --work-package RF-21 node tools/nexus-id.mjs catalog validate        # npm run validate node tools/nexus-id.mjs catalog list --scope GRX node tools/nexus-id.mjs export NXS-STD-ST-000001 --format zenodo
ZitierenNS-1, clause 8. NXS-STD-ST-000001@0.1.0. https://nexustandards.com/standards/ns-1/#nx-c-8

8. Der Stack offener Standards

registry/open-standards-stack.yaml legt die externen Standards und Indizes unter der UNI. the network's own records überführt einen Datensatz in die Metadaten von Zenodo-Hinterlegungen, DataCite 4.5, Schema.org JSON-LD (für Landingpages und Google Dataset Search), CodeMeta 3.0 und CITATION.cff; zenodoClient.ts Hinterlegungen bei Zenodo (standardmäßig Sandbox, standardmäßig Probelauf, Token von der veröffentlichenden Institution bereitgestellt) nach dem rechtlichen Gate zenodoDepositEligibility (APPROVED, open or embargoed, SPDX licence). The returned DOI is written back as relatedIdentifiers[IsIdenticalTo, DOI], so the UNI stays the key and the DOI is the citable crosswalk. Zenodo is registered in the network's legal texts#zenodo und external-apis.yaml#zenodo.deposit at LEGAL_REVIEW_REQUIRED.

Laufzeit-Hooks (NS-6): raumgebundene Quellen akzeptieren uniKey, jede RoomSourceProjection trägt uni und die Raumansicht verweist darauf; Pässe tragen PASSPORT_UNI_FIELD im gemeinsamen Abschnitt Identität mit Format uni; jede JSON-API-Antwort mit einem uni trägt X-Nexus-UNI; /api/uni serves the catalogue and exports. The Global Risks Index (NXS-GRX) recordUni übernimmt die NS-1-Grammatik für neue Datensätze, wobei Kennungen mit Punkten beibehalten werden als legacyUni (NS-3).

ZitierenNS-1, clause 9. NXS-STD-ST-000001@0.1.0. https://nexustandards.com/standards/ns-1/#nx-c-9

9. Verhältnis zu den anderen Standards

  • Namensarchitektur (the network's own records): öffentliche Anzeigenamen und Markenschutz. NS-1 ist die darunterliegende maschinenlesbare Ebene; beide widersprechen sich nie, da Codes nie Namen sind.
  • Claim Registry (the network's own records): claimCeiling on every record.
  • Rechtsregister (the network's legal texts/**): legalState, publisherRef, rights.license.
  • UNI identifier fabric (V3 directive section 12): artefacts are allocated by the catalogue file (reconstructable source, served by /api/uni und /uni); NXS-GRX -Datensätze werden von PostgreSQL vergeben nexus_uni (NS-3, the network's own records).
  • Work items: every work item lists the UNIs it creates or changes in evidenceOutputs.
ZitierenNS-1, clause 10. NXS-STD-ST-000001@0.1.0. https://nexustandards.com/standards/ns-1/#nx-c-10

10. Anschlusspakete

Delivered: NS-3 NXS-GRX record UNIs (allocation, grammar, crosswalk; WDI bootstrap in use), NS-3b STAC, DCAT and PROV-O profile (the network's own records), NS-6 Oberflächenverdrahtung, NS-7 Resolver-Landingpages. Offen: NS-2 Zitier- und Namensnennungsformat · Übernahme des Datensatz-Allokators pro Pfad (realDataObservationIngest, Open-Data-Ingests) · NS-4 Dokumentvorlage mit uni front matter · NS-5 figure, map and visualisation standard (with the UI/UX kit) · NS-7b SPA landing-page meta tags and sitemap · NS-8 Zenodo publishing workflow with legal gate, DOI write-back and Software Heritage archival.

Änderungshistorie

Versions from the catalogue; entries from the changelog that name this document.

VersionDatumHinweis
0.1.015 October 2026current version in the catalogue
  • Unveröffentlichter Vorschlag NS-13 NXS-STD-PC-000004 (OFFEN; die letzte Einreichungsfrist endet am 2026-11-16), der erste Vorschlag, der als Datensatz geführt wird unter proposals/ und geprüft von npm run validate: NS-1 Abschnitt 1.1 legt die Zuweisungsregeln für Kontextcodes CA-1 bis CA-10 sowie die Regeln NS1-R8 bis NS1-R10 fest. Reservierte und benutzerdefinierte Codeelemente nach ISO 3166-1 sowie Codes nach ICAO Doc 9303 werden nun abgelehnt. AAP genießt Bestandsschutz. Es schlägt vier Codes für Technologiedomänen vor: CMP Rechen- und beschleunigte Infrastruktur, DTW digitale Zwillinge und Simulation, SNS Sensorik- und Messnetze sowie PNT Positionsbestimmung, Navigation und Zeitgebung. Das Domänenregister wird zu schemaVersion 1.1.0 (Nebenversion, additiv).
  • 0.1.0 – 2026-10-16 NS-1 (the UNI and the artefact catalogue), NS-3 (NXS-GRX record UNIs) and NS-3b (STAC, DCAT, PROV-O profile) as PROPOSED documents under standards/.
03Forschung

Forschung, Quellen und Dateien

Aktuelle Forschung zu NS-1

Aktuelle begutachtete Artikel, Preprints, Datensätze und Berichte zum Thema dieses Standards, zum Zeitpunkt des Lesens aus offenen wissenschaftlichen Metadatendiensten (OpenAlex, Crossref, DataCite, Zenodo, arXiv, Europe PMC, OpenAIRE Graph) mit aus dem Registry gebildeten Suchbegriffen abgerufen. Jedes Werk wird mit Autoren, Publikationsort, Jahr, Typ, Open-Access-Status und Lizenz aufgeführt und verlinkt auf seine DOI oder Landingpage. Quellen, die auf dieser Website noch nicht für die Live-Anzeige freigeschaltet sind, werden zur Referenz aufgeführt und nicht abgefragt.

Search termspersistent identifier; persistent identifiers; digital object identifier; PID infrastructure; PID graph; DataCite Metadata Schema; in-toto Attestation Frameworkcombined with: research; data; metadata; infrastructure; FAIRDerived from the subject of the standard and its rules, and the external standards of its crosswalk domains.

  • OpenAlexlisted for reference; not queried
  • Crossreflisted for reference; not queried
  • DataCitelisted for reference; not queried
  • Zenodolisted for reference; not queried
  • arXivzur Referenz aufgeführt; nicht abgefragt
  • Europe PMClisted for reference; not queried
  • OpenAIRE Graphlisted for reference; not queried

Auf dieser Website ist derzeit keine Quelle für die Live-Anzeige aktiviert: Die Quellen sind zur Orientierung aufgeführt, keine wird abgefragt. Sobald die maßgebliche herausgebende Stelle eine Quelle nach Prüfung ihrer Bedingungen aktiviert, werden hier aktuelle Arbeiten aufgelistet. Nur Metadaten und Links: Titel, Autoren, Publikationsorgan, Jahr, Typ, Open-Access-Status und Lizenz, wie jede Quelle sie erfasst; die Arbeiten werden zur Orientierung aufgeführt, nicht geprüft oder empfohlen.

04In der Praxis

Wo er gilt und wie er entwickelt wird

Wie er entwickelt wird und wie man mitwirkt, der Standard als Prozess und die Programmbereiche, die ihn aufführen.

How NS-1 is developed, and how to take part

NS-1 wird offen nach NS-13 entwickelt (die Phasen und Gates von NS-13). Arbeitsgruppen erstellen Entwürfe, Räte entscheiden die vorbehaltenen Angelegenheiten, und jede Person kann ohne Mitgliedschaft oder Gebühr eine Änderung vorschlagen, kommentieren, einen Umsetzungsbericht einreichen, Einspruch erheben oder Beschwerde einlegen.

05Externe Standards

Beziehung zu externen Standards

NS-1 verweist auf externe Standards durch Kennung, Klauselnummer und URL (NS14-R1) und leitet die Leserschaft an die herausgebende Stelle weiter.

06Im gesamten Netzwerk

Lernen, das Netzwerk und Fragen

Kurse und Fachgebiete der Risk Academy

1 course and 2 disciplines of Risk Academy (risksacademy.com) that teach the knowledge and methods of NS-1. Each course lists its level, stream and learning hours.

Kurse

Disziplinen

Die Zuordnung zwischen Kursen, Fachgebieten und den Nexus Standards wird mit der Risk Academy geführt und unterliegt deren akademischer Prüfung.

BerichteBeitragen

Evidenz von dieser Seite aus beitragen.

Die Berichte sind die vierteljährliche Publikation des Konsortiums. Was Sie über dieses Thema wissen, kann in der nächsten Ausgabe zu Evidenz, einem Fall oder einer Korrektur werden, mit Nennung Ihres Namens und unter CC BY 4.0 veröffentlicht, sofern es Ihr eigenes Werk ist.

Nexus Standards
Normen

Wirken Sie an den Standards mit.

Regierungen, Regulierungsbehörden, Normungsgremien, Wirtschaft, Wissenschaft und Gemeinschaften sind eingeladen, den Katalog vor seiner ersten offiziellen Veröffentlichung, die für 2030 angestrebt wird, mitzugestalten: einen Entwurf kommentieren, eine Änderung vorschlagen, einer Arbeitsgruppe beitreten oder eine Feldübung ausrichten.

Status und Nutzung. Die Nexus Standards sind vorgeschlagene Standards, die in einem offenen Verfahren nach NS-13 entwickelt und zur freiwilligen Nutzung veröffentlicht werden; sie stellen keine Zertifizierung, Akkreditierung oder behördliche Genehmigung dar, und die Annahme bleibt eine Entscheidung des Global Standards Council und, in jedem Land, seines National Standards Council. Eine UNI (Unique Nexus Identifier) identifiziert ein Artefakt; sie zertifiziert es nicht. Die Namen von Normungsorganisationen und ihren Standards gehören deren Trägern und werden nur zur Identifizierung der Dokumente verwendet; kein Text eines externen Standards wird hier wiedergegeben. Nexus Standards ist mit keiner hier genannten Normungsorganisation verbunden, wird von keiner unterstützt und ist von keiner zertifiziert.

Lizenzen: CC BY 4.0 für Standardtexte, Register, Schemata und Daten; Apache-2.0 für Referenzcode. Externe Standards werden mit Name, Nummer und Link unter ihren eigenen Lizenzen zitiert. Daten, Bibliotheken und Schriften Dritter behalten ihre eigenen Lizenzen: siehe Hinweise Dritter.